SC[BJ13-10kV Epoxy cast dry-type transformers
Key words:
Classification:
Keyword: SC[BJ13-10kV Epoxy cast dry-type transformers
E-mail:
- Detail
-
- Commodity name: SC[BJ13-10kV Epoxy cast dry-type transformers
Scope of application
This product has a wide range of applications,especially suitable for use in places with high fire protection requirements,such as mines,oil felds,subways,power plants,schools,hospitals,commercial centers,high-rise buildings and all indoor configuration systems.
Model meaning

Working conditions
Installation of high seat:the altitude does not exceed 1000m;
Waveform of power supply voltage:similar to sine wave;
Polyphase supply voltage symmetry:The supply voltage connected to the polyphase transformer should be approximately symmetrical.
Ambient temperature:maximum temperature +40°℃;Maximum daily average temperature +30°℃;Maximum annual average temperature +20℃;Minimum air temperature-25℃(for indoor transformers).
Structural features
*Core iron
The core is made of high magnetic permeability and high-quality grain oriented cold bonded silicon steel sheet,45°general step joint, the core is made of special square tube pull plate structure,the core column is bound with insulation tape,and the surface of the core is coated with special resin to prevent rust prevention,which effectively reduces no-load loss,no-load current and core noise.
Safe,fire retardant,no pollution,can be installed directly in the load center.
Maintenance-free,easy installation,low overalloperating cost.
Good moisture-proof performance,it can operate normally under 100%humidity,and can be put into operation without pre-drying after shutdown.
Low loss,low local discharge,low noise,strong heat dissipation capacity,equipped with a perfect temperature protection and control system,to provide reliable guarantee for the safe operation of the transformer.
High reliability.According to the operation study of the products that have been put into operation,the reliability index of the products has reached the international advanced level.
*Foil coil
The low voltage winding is made of whole copper foil,together with F grade turn insulation,on a special low voltage foil winding machine.The foil coil solves the outstanding problems of low voltage and high current coil winding,such as large short circuit stress, unbalanced ampere-turns,poor heat dissipation effect,spiral winding Angle and unstable welding quality.At the same time,the end of the winding of our company is sealed with resin,solidified and formed to prevent lake and pollution.
*Temperature control device
The transformer adopts BWDK series signal thermometer,and the temperature measuring element is buried in the upper part of the low- voltage coil,which can automaticallydetect and return to display the respective working humidity of the three-phase coil.And it has ultra high temperature alarm and tripping function.
*Voltage conversion
The connection piece can realize the conversion of 10kV and 20kV voltage in different gears,which is suitable for the voltage requirements of 10kV and 20kV system respectively.
Main technical parameters
SCB136KV,10KV class 13 dry-type non-excitation voltage regulation distribution transformer no-load loss and load lossRated Capacity(kVA) No-loadloss
(kW)Load losses at different insulation system temperatures Short-
circuit impedance
(%)130℃(B)
(100℃)155℃(F)
(120℃)180℃(H)
(145℃)30 0.135 0.605 0.640 0.685 4.0 50 0.195 0.845 0.900 0.965 80 0.265 1.16 1.4 1.33 100 0.290 1.33 1.41 1.52 125 0.340 1.56 1.66 1.78 160 0.385 1.80 1.91 2.02 200 0.445 2.13 2.27 2.44 250 0.515 2.33 2.48 2.66 315 0.635 2.94 3.12 3.35 400 0.705 3.37 3.59 3.85 500 0.835 4.13 4.39 4.70 630 0.965 4.97 5.29 5.66 630 0.935 5.05 5.36 5.76 6.0 800 1.09 5.89 6.26 6.71 1000 1.27 6.88 7.31 7.88 1200 1.50 8.19 8.72 9.33 1600 1.76 9.94 10.5 11.3 2000 2.19 1.22 13.0 14.0 2500 2.59 14.5 15.4 16.6 1600 1.76 11.0 11.6 12.5 2000 2.19 13.5 14.3 15.4 8.0 2500 2.59 15.9 17.0 18.2
Note:The load loss listed in the table is the value of the reference temperature of diferent insulation systems in brackets (see GB1094.11).The load loss of other insulation system temperatures not included in the table shall be converted according to thee respective reference temperature and the data of the humidity of the insulation system of"155℃(F)"as a reference.
Environmentally friendly gas-insulated metal enclosed switchgear is the most commonly used three-phase intelligent gas-insulated AC cabinet and is widely used in various switchgear sets, with population concentration in the country, the power market must be supported, environmentally friendly gas-insulated switchgear will also grow with market development; market potential is yet to be tapped. At the same time, as the product integrates data collection and management, data processing and storage, online monitoring of switchgear, advanced analysis, and other multifunctions in one, network intelligent monitoring and management of the distribution network, so that the distribution network operates in a safe, reliable, high-quality, and efficient best state, to achieve remote monitoring, management, and control of the power system distribution network, to achieve network optimization, safe electricity use, power management, energy saving, and consumption reduction; at the same time, the system can be widely used in intelligent power distribution fields such as transportation, factories, hospitals, schools, buildings, residential areas, and commercial office buildings.
Related products
Message
* Leave your contact details to receive free product quotes