ZN85-40.5 Series indoor vacuum circuit breakers

ZN85-40.5/T2ooo-31.5 type indoor high voltage vacuum circuit breaker (hereinafter I referred to as breaker) For three-phase AC 50Hz, rated voltage 40.5KV Power Meter I system, for industrial and mining enterprises, Cut-off power plants and substations as Iload current, overload current, fault current use.
Using the upper and lower circuit breaker and operating mechanism layout structure. 1 eff ectively reducing the circuit breaker depth.
Three-phase interrupter and associated live parts by the three independent isolated I epoxy insulating tube to form Composite insulation, circuit breakers under normal operating! conditions to meet the air distance and creepage distance requirements, and Eff ectively] reduces the size of the circuit breaker. Led and electric circuit interrupter installed in the static ] conductive connection Insulation barrel, magnitude and angle pitch of only 300mm. All main I circuit electrical connection fi xed connection, With high reliability. Insulation installed in the! circuit breaker frame above the cylinder.
The new circuit breaker designed for the spring actuator, installed in the circuit breaker I within the framework of Its structural features more suitable arrangement of vacuum circuit I breakers up and down, turn off a circuit breaker in the overall structure Inseparable part of the cut. Mechanical design is simple, the output curve is more suitable for vacuum circuit 40.5KV Device characteristics and requirements.
Overall layout is reasonable, beautiful, simple. Compact, fl exible operation, with electrica1 properties Reliable, long life, easy maintenance, institutional maintenance features.
Frequent operation of the circuit breaker and apply a variety of occasions and running conditions are harsh places.;

Key words:

Keyword: ZN85-40.5 Series indoor vacuum circuit breakers

  • Detail
    • Commodity name: ZN85-40.5 Series indoor vacuum circuit breakers

    ZN85-40.5/T2ooo-31.5 type indoor high voltage vacuum circuit breaker (hereinafter I referred to as breaker) For three-phase AC 50Hz, rated voltage 40.5KV Power Meter I system, for industrial and mining enterprises, Cut-off power plants and substations as Iload current, overload current, fault current use.<br> Using the upper and lower circuit breaker and operating mechanism layout structure. 1 eff ectively reducing the circuit breaker depth.<br> Three-phase interrupter and associated live parts by the three independent isolated I epoxy insulating tube to form Composite insulation, circuit breakers under normal operating! conditions to meet the air distance and creepage distance requirements, and Eff ectively] reduces the size of the circuit breaker. Led and electric circuit interrupter installed in the static ] conductive connection Insulation barrel, magnitude and angle pitch of only 300mm. All main I circuit electrical connection fi xed connection, With high reliability. Insulation installed in the! circuit breaker frame above the cylinder. <br> The new circuit breaker designed for the spring actuator, installed in the circuit breaker I within the framework of Its structural features more suitable arrangement of vacuum circuit I breakers up and down, turn off a circuit breaker in the overall structure Inseparable part of the cut. Mechanical design is simple, the output curve is more suitable for vacuum circuit 40.5KV Device characteristics and requirements.<br> Overall layout is reasonable, beautiful, simple. Compact, fl exible operation, with electrica1 properties Reliable, long life, easy maintenance, institutional maintenance features.<br> Frequent operation of the circuit breaker and apply a variety of occasions and running conditions are harsh places.;

    Model implication



    Main technical parameters

    S/N Items Unit Data
    01  Rated voltage kV 40.5 
    02  Rated Current kV 1250   1600   2000
    03  Rated Frequency A 50 
    04  Rated short circuit breaking current kA 25  31.5 
    05  Rated short-circuit close current(peak) kA 63  80 
    06  rated short-circuit withstand current kA 25  31.5 
    07  Rated peak withstand current kA 63  80 
    08  1min Power frequency withstand voltage kV 95 
    09  Lightning impulse withstand voltage(rated breaking before and after) kV 185 
    10  Rated operating sequence   o-0.3s-co-180s-co
    11  Rated short-circuit current breaking times Times 20 
    12  Mechanical life Times 10000 
    13  Breaking time V ≤80
    14  Single capacitor bank breaking current V 630 
    15  Back to back capacitor bank breaking current mm 400 
    16  Rated operating voltage mm -100/~110,-220/~200


    Physical dimension

     

     

Environmentally friendly gas-insulated metal enclosed switchgear is the most commonly used three-phase intelligent gas-insulated AC cabinet and is widely used in various switchgear sets, with population concentration in the country, the power market must be supported, environmentally friendly gas-insulated switchgear will also grow with market development; market potential is yet to be tapped. At the same time, as the product integrates data collection and management, data processing and storage, online monitoring of switchgear, advanced analysis, and other multifunctions in one, network intelligent monitoring and management of the distribution network, so that the distribution network operates in a safe, reliable, high-quality, and efficient best state, to achieve remote monitoring, management, and control of the power system distribution network, to achieve network optimization, safe electricity use, power management, energy saving, and consumption reduction; at the same time, the system can be widely used in intelligent power distribution fields such as transportation, factories, hospitals, schools, buildings, residential areas, and commercial office buildings.